Avocent ECMS2000U Uživatelská příručka Strana 39

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 92
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 38
Chapter 3: Operations 33
Navigating the serial menu
To navigate through the serial menu, type the number or letter that corresponds to the option you
wish to choose and press
Enter. This action will bring you to a sub-menu or to a screen where you
can make configuration changes. To exit a menu or screen and to confirm any configuration
changes you have made, type
0 (zero) and press Enter. To navigate back up through the menus,
continue to type 0 and press Enter at each screen.
Configuring Network Settings
Each Emerge digital extender system component is shipped with default network settings
preconfigured for your ECMS user station and transmitter. You can change the default values for
your system using the serial menu. If you wish, you can place the user station on a different subnet
from the transmitter.
NOTE: IP address data can be obtained by DHCP or can be set to Static.
NOTE: It is recommended that you configure the network settings for the transmitter before you configure the
network settings for the ECMS user station.
To configure network settings for the transmitter:
1. Press Enter to display the serial menu. The Appliance Selection Menu displays.
2. Press 2 to access the Transmitter Menu. If the password option is enabled, you will be
prompted for a password.
3. Type the password and press Enter. The Transmitter Main Menu will appear.
Figure 3.9: Transmitter Main Menu
NOTE: The Reset Appliance option in the Transmitter Main Menu applies only to network settings.