14 Equinox ESP-2 MI Serial Hub Installation Guide
Displaying or Changing Network Configuration Values
The Network Configuration window displays the ESP-2 MI unit’s IP address, subnet mask and
gateway address. You must configure a nondefault IP address for the ESP-2 MI before the unit
becomes operational.
To display or change network configuration values:
1. Select Network Con guration from the Main Menu.
2. Enter a valid value in the IP Address, Subnet Mask and Gateway Address elds. The
addresses must be entered in standard IP dot notation. The gateway address must be in the
same subnet as the IP address.
You cannot set the IP address to: a Class A address of 0.0.x.x, a loopback address of
127.x.x.x, the default value of 192.1.1.1 or an address at or above 248.x.x.x.
3. If you changed any values, click the Apply button. The EEPROM con guration is
modi ed, but the change does not take effect until the next reboot of the ESP-2 MI. To
reboot, click the Reboot button. If the IP address had not been previously set, the unit
reboots automatically.
Displaying or Changing Port Configuration Values
The Port Configuration window displays the interface type for each port. The interface type is
set with jumpers inside the chassis; it cannot be configured in software. If a port is configured for
RS-485, the display indicates the current transfer mode, which can be changed via this window.
To display or change port configuration values:
1. Select Port Con guration from the Main Menu.
2. To see the procedure for changing the jumpers that set the interface type, click the show
how to change jumpers link.
3. The Interface Type eld indicates the port’s interface type: RS232, RS422 or RS485.
4. The Transfer Mode (RS485) eld indicates the current transfer mode if the Interface Type
is RS485. (If the port uses another interface type, this eld indicates Not Applicable). To
change the transfer mode, select RTS or ADDC from the Transfer Mode (RS485) listbox.
5. If you changed the transfer mode, click the Apply button. The EEPROM con guration is
modi ed, but the change does not take effect until the next reboot of the ESP-2 MI. To
reboot, click the Reboot button.
Displaying Hardware Information
The Hardware Information window displays the following items:
• Model number
Hardware revision number
Number of serial ports
EEPROM revision number
Amount of SDRAM in megabytes
Amount of FLASH memory in megabytes