For Technical Support:
Avocent Corporation
4991 Corporate Drive
Huntsville, Alabama 35805-6201 USA
Tel: +1 256 430 4000
Fax: +1 256 430 4031
Avocent International Ltd.
Avocent House, Shannon Free Zone
Shannon, County Clare, Ireland
Tel: +353 61 715 292
Fax: +353 61 471 871
Avocent Asia Pacific
Singapore Branch Office
100 Tras Street, #15-01
Amara Corporate Tower
Singapore 079027
Tel: +656 227 3773
Fax: +656 223 9155
Avocent Germany
Gottlieb-Daimler-Straße 2-4
D-33803 Steinhagen
Germany
Tel: +49 5204 9134 0
Fax: +49 5204 9134 99
Avocent Canada
20 Mural Street, Unit 5
Richmond Hill, Ontario
L4B 1K3 Canada
Tel: +1 877 992 9239
Fax: +1 877 524 2985
www.avocent.com/support
Installer/User Guide
For models: 1415, 1515 and 2015
AutoView
®
Switch
Zobrazit stránku 0
1 2 3 4 5 6 ... 133 134

Shrnutí obsahu

Strany 1 - AutoView

590-644-616AFor Technical Support: Avocent Corporation4991 Corporate DriveHuntsville, Alabama 35805-6201 USATel: +1 256 430 4000 Fax: +1 256 430 4031A

Strany 2

viii AutoView 1415/1515/2015 Switch Installer/User GuideFigure 4.2: User Setup Menu (Administrator Only)...

Strany 3 - 1415/1515/2015

22 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Figure 3.2 : Boîte de dialogue Configuration (utilisateur)Figu

Strany 4

Chapitre 3 : Opérations de base 23Figure 3.4 : Boîte de dialogue NomsNOTA : Si la liste de serveurs est modifiée, le curseur de la souris se t

Strany 5

24 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015NOTA : Si aucun nom n’a été attribué à un module AVRIQ, le num

Strany 6

Chapitre 3 : Opérations de base 25Figure 3.7 : Boîte de dialogue Modif. équip.3. Choisissez le nombre de voies prises en charge par le commuta

Strany 7 - Table of Contents

26 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Choix de l’ordre d’affichage par défaut des serveurs :1. Sélec

Strany 8

Chapitre 3 : Opérations de base 27Figure 3.9 : Boîte de dialogue ClavierModification du paramètre régional du clavier :1. Appuyez sur Impr écr

Strany 9 - List of Figures

28 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/20153. Sélectionnez la langue souhaitée.4. Cliquez sur OK pour enr

Strany 10

Chapitre 3 : Opérations de base 29Figure 3.12 : Boîte de dialogue IndicateurAffichage de l’indicateur d’état :1. Sélectionnez Nom ou EID pour

Strany 11 - List of Tables

30 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015lorsque la console reste inutilisée pendant un temps d’inactiv

Strany 12

Chapitre 3 : Opérations de base 31Protection de la console par un mot de passe :1. Définissez le mot de passe en suivant la procédure décrite

Strany 13 - Product Overview

ixList of TablesTable 2.1: Legacy Switch Support...12

Strany 14

32 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015-ou-Si votre console est protégée par un mot de passe, voyez l

Strany 15

Chapitre 3 : Opérations de base 33Désactivation de l’économiseur d’écran :1. Dans la boîte de dialogue Sécurité, décochez la case Activer Écon

Strany 16 - Safety Precautions

34 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Figure 3.16 : Boîte de dialogue Sélec. Équip. (administrateur)

Strany 17

Chapitre 3 : Opérations de base 35Figure 3.18 : Boîte de dialogue Version du firmwareDésactivation d’un module AVRIQLa désactivation d’un modu

Strany 18

36 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Ajout de serveurs à la liste de balayage1. Si l’interface OSCA

Strany 19 - Installation

Chapitre 3 : Opérations de base 37Figure 3.20 : Boîte de dialogue CommandesNOTA : La figure 3.20 représente l’écran Commandes de l’administrat

Strany 20

38 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015La boîte de dialogue Diagnostics s’affiche. La partie supérieu

Strany 21 - (for updating firmware)

Chapitre 3 : Opérations de base 39Lancement des tests de diagnostic :1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran. La boît

Strany 22 - Cascading AutoView Switches

40 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Figure 3.23 : Boîte de dialogue DiffusionNOTA : Diffusion des

Strany 23 - AutoView switch

Chapitre 3 : Opérations de base 41Figure 3.24 : Boîte de dialogue Activer diffusion5. Cliquez sur OK pour activer la diffusion. Cliquez sur X

Strany 24 - Adding Legacy Switches

x AutoView 1415/1515/2015 Switch Installer/User Guide

Strany 25 - PS/2, USB, Sun and serial

42 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Figure 3.25 : Boîte de dialogue Commutateur3. Sélectionnez au

Strany 26

43CHAPITRE4Opérations avancéesUtilisation des privilèges d’administrateurLes commutateurs AutoView 1415/1515/2015 permettent à quatre utilisateurs et

Strany 27

44 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Figure 4.2 : Menu Utilisateur (administrateur uniquement)Fonct

Strany 28

Chapitre 4 : Opérations avancées 45Figure 4.3 : Menu Modifier utilis. (administrateur uniquement)Le champ Nom utilis. affiche des noms par déf

Strany 29 - Basic Operations

46 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Le bouton Tout Suppr. permet à l’administrateur de refuser l’a

Strany 30

47AnnexesAnnexe A : Mises à jour FlashMise à jour du commutateur AutoViewAvocent fournit un utilitaire spécifique vous permettant de mettre à jour le

Strany 31

48 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015• Vérifiez qu'une seconde exécution du programme Applianc

Strany 32

Annexes 49Figure A.2 : Boîte de dialogue Mise à jour AVRIQ

Strany 33

50 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Annexe B : Spécifications techniquesTableau B.1 : Spécificati

Strany 34 - Assigning server names

Annexes 51Spécifications produit du commutateur AutoViewTension nominale d’alimentation (c.a.)100 à 240 V c.a. détection automatiqueIntensité

Strany 35 - Figure 3.4: Names Dialog Box

1CHAPTER1Product OverviewFeatures and BenefitsThe AutoView® 1415/1515/2015 switches integrate Avocent field-proven analog keyboard, video and mouse (K

Strany 36 - Assigning device types

52 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Annexe C : Émulation des touches avancées du clavier SunIl est

Strany 37 - Changing the display behavior

Annexes 53Par exemple : Pour Arrêt + A, maintenez les touches Ctrl+Maj+Alt enfoncées et appuyez sur Arrêt défil, puis sur F1 + A.Ces combinai

Strany 38 - Print Screen as the default

54 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Annexe D : Assistance techniqueNotre équipe d’assistance techn

Strany 39 - Selecting a language

USA NotificationWarning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s au

Strany 40 - Controlling the status flag

590-644-616DFor Technical Support: Avocent Corporation4991 Corporate DriveHuntsville, Alabama 35805-6201 USATel: +1 256 430 4000 Fax: +1 256 430 4031A

Strany 41 - Setting console security

2 AutoView 1415/1515/2015 Switch Installer/User GuideTwo-User Share ModeThe AutoView 1415/1515/2015 switches feature a Share Mode function that

Strany 42 - Appendix D:Technical Support

Chapter 1: Product Overview 3Cascading expansionEach AutoView switch supports up to 16 directly attached servers and can conveniently scale to

Strany 43 - ENERGY STAR

4 AutoView 1415/1515/2015 Switch Installer/User GuideFigure 1.1: Example of an AutoView Switch ConfigurationSafety PrecautionsTo avoid potentia

Strany 44

Chapter 1: Product Overview 5• Use only with grounded outlets at both the computer and monitor. When using a backup Uninterruptible Power Supp

Strany 45

6 AutoView 1415/1515/2015 Switch Installer/User Guide

Strany 46 - AVRIQ module

7CHAPTER2InstallationGetting StartedBefore installing your AutoView switch, refer to the following list to ensure you have all items that shipped with

Strany 47 - Scanning Your System

USA NotificationWarning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s au

Strany 48 - Figure 3.19: Scan Dialog Box

8 AutoView 1415/1515/2015 Switch Installer/User GuideFigure 2.1: AutoView Switch Horizontal InstallationCAUTION: Rack Loading - Overloading or

Strany 49 - Running System Diagnostics

Chapter 2: Installation 9CAUTION: To reduce the risk of electric shock or damage to your equipment - - Do not disable the power cord grounding

Strany 50

10 AutoView 1415/1515/2015 Switch Installer/User GuideTo connect a server using an AVRIQ module:1. Locate the AVRIQ modules for your AutoView s

Strany 51 - Broadcasting to Servers

Chapter 2: Installation 11In this configuration, the local port OSCAR interface is disabled in switches cascaded below the main AutoView switc

Strany 52 - Escape to

12 AutoView 1415/1515/2015 Switch Installer/User GuideFigure 2.3: AutoView 2015 Switch Configuration with a Cascaded Switch Adding Legacy Swit

Strany 53 - Changing Your Switch Mode

Chapter 2: Installation 13Figure 2.4: AutoView 2015 Switch Configuration with Legacy KVM Switches Local Analog User AAutoView 2015 SwitchAVRI

Strany 54 - Escape to cancel

14 AutoView 1415/1515/2015 Switch Installer/User GuideFigure 2.5: AutoView Switch Configuration with AutoView 1415/1515/2015 SwitchesNOTE: The

Strany 55 - Advanced Operations

Chapter 2: Installation 15To add a legacy KVM switch:1. Mount the primary KVM switch into your rack cabinet. 2. Connect one end of a CAT 5 cab

Strany 56

16 AutoView 1415/1515/2015 Switch Installer/User Guide

Strany 57 - in the User Setup menu

17CHAPTER3Basic OperationsControlling Your System at the Analog PortsThe AutoView switch features one or two analog port sets on the back of the switc

Strany 58 - on the User Setup screen

AutoView® Switch1415/1515/2015Installer/User GuideAvocent, the Avocent logo, The Power of Being There, AutoView, OutLook and OSCAR are registered trad

Strany 59 - Appendices

18 AutoView 1415/1515/2015 Switch Installer/User GuideNOTE: You can also press the Control key twice, the Alt key twice or the Shift key twice

Strany 60 - Auto-upgrade

Chapter 3: Basic Operations 19To select the previous server:Press Print Screen and then Backspace. This key combination toggles you between th

Strany 61 - Appendices 49

20 AutoView 1415/1515/2015 Switch Installer/User GuideThis Keystroke Does ThisF1Opens the Help screen for the current dialog box.EscapeCloses t

Strany 62

Chapter 3: Basic Operations 21Configuring OSCAR Interface MenusYou can configure your AutoView switch from the Setup menu within the OSCAR int

Strany 63

22 AutoView 1415/1515/2015 Switch Installer/User GuideFigure 3.2: Setup Dialog Box (User)Figure 3.3: Setup Dialog Box (Admin)NOTE: Figure 3.3 d

Strany 64

Chapter 3: Basic Operations 23Figure 3.4: Names Dialog BoxNOTE: If the server list changes, the mouse cursor will turn into an hourglass as th

Strany 65 - F12 performs a Windows

24 AutoView 1415/1515/2015 Switch Installer/User GuideNOTE: If an AVRIQ module has not been assigned a name, the EID is used as the default nam

Strany 66 - Appendix D: Technical Support

Chapter 3: Basic Operations 25Figure 3.7: Device Modify Dialog Box3. Choose the number of ports supported by your cascaded switch and click OK

Strany 67

26 AutoView 1415/1515/2015 Switch Installer/User GuideTo choose the default display order of servers:1. Select Name to display servers alphabet

Strany 68

Chapter 3: Basic Operations 27Figure 3.9: Keyboard BoxTo change the keyboard country code:1. Press Print Screen to launch the OSCAR interface.

Strany 69 - Commutateur

InstructionsThis symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literatur

Strany 70

28 AutoView 1415/1515/2015 Switch Installer/User Guide3. Select your desired language.4. Click OK for changes to take effect.Figure 3.11: Langu

Strany 71

Chapter 3: Basic Operations 29Figure 3.12: Flag Dialog BoxTo determine how the status flag is displayed:1. Select Name or EID to determine wha

Strany 72

30 AutoView 1415/1515/2015 Switch Installer/User GuideOnce engaged, your console will remain locked until you press any key or move the mouse.

Strany 73 - TABLE DES MATIÈRES

Chapter 3: Basic Operations 313. Type the number of minutes for Inactivity Time (from 1 to 99) to delay activation of password protection and

Strany 74

32 AutoView 1415/1515/2015 Switch Installer/User Guide4. Choose Energy if your monitor is ENERGY STAR compliant; otherwise select Screen.CAUTIO

Strany 75 - LISTE DES FIGURES

Chapter 3: Basic Operations 33To turn off the screen saver:1. In the Security dialog box, clear Enable Screen Saver.2. Click OK.To immediately

Strany 76

34 AutoView 1415/1515/2015 Switch Installer/User GuideFigure 3.16: Target Selection Dialog Box (Admin)4. Select an AVRIQ or IAC module to view

Strany 77 - LISTE DES TABLEAUX

Chapter 3: Basic Operations 35Figure 3.18: Firmware Warning Dialog BoxTo decommission an AVRIQ module:Decommissioning an AVRIQ module restores

Strany 78

36 AutoView 1415/1515/2015 Switch Installer/User GuideTo add servers to the scan list:1. If the OSCAR interface is not open, press Print Screen

Strany 79 - Présentation du produit

Chapter 3: Basic Operations 37Figure 3.20: Commands Dialog BoxNOTE: Figure 3.17 shows the Commands screen for the administrator and local user

Strany 81

38 AutoView 1415/1515/2015 Switch Installer/User GuideNOTE: AVRIQ or IAC modules may appear to be offline while being upgraded.Figure 3.21: Dia

Strany 82 - Mesures de sécurité

Chapter 3: Basic Operations 39Figure 3.22: Diagnostics Warning Dialog Box3. Click OK to begin diagnostics.-or-Click X or press Escape to exit

Strany 83

40 AutoView 1415/1515/2015 Switch Installer/User GuideFigure 3.23: Broadcast Dialog BoxNOTE: Broadcasting Keystrokes - The keyboard state must

Strany 84

Chapter 3: Basic Operations 41Figure 3.24: Broadcast Enable Confirm/Deny Dialog Box5. Click OK to enable the broadcast. Click X or press Escap

Strany 85

42 AutoView 1415/1515/2015 Switch Installer/User GuideFigure 3.25: Switch Dialog Box3. Select either Preemptive or Cooperative as your Switch M

Strany 86

43CHAPTER4Advanced OperationsUsing Administrator PrivilegesThe AutoView 1415/1515/2015 switches allow up to four users and one administrator to log in

Strany 87

44 AutoView 1415/1515/2015 Switch Installer/User GuideFigure 4.2: User Setup Menu (Administrator Only)User Setup menu functions (administrator

Strany 88 - Connexion d’utilisateurs

Chapter 4: Advanced Operations 45Figure 4.3: User Edit Menu (Administrator Only)The Username field displays default names that can be edited b

Strany 89 - AutoView principal

46 AutoView 1415/1515/2015 Switch Installer/User GuideThe Clear All button allows the administrator to clear access to all ports for a given us

Strany 90

47AppendicesAppendix A: Flash UpgradesUpgrading the AutoView switchYou can upgrade the firmware of your AutoView switch by using a special update util

Strany 92 - Modules série, PS/2

48 AutoView 1415/1515/2015 Switch Installer/User Guide• In the selected COM port Advanced Port settings, verify that the FIFO buffers are selec

Strany 93

Appendices 49Figure A.2: AVRIQ Upgrade Dialog Box

Strany 94

50 AutoView 1415/1515/2015 Switch Installer/User GuideAppendix B: Technical SpecificationsTable B.1: Product SpecificationsAutoView Switch Pro

Strany 95 - Opérations de base

Appendices 51AutoView Switch Product SpecificationsAC-input voltage rating100 to 240 VAC AutosensingAC-input current rating 0.5 AAC-input cab

Strany 96 - Modification de

52 AutoView 1415/1515/2015 Switch Installer/User GuideAppendix C: Sun Advanced Key EmulationCertain keys on a standard Type 5 (US) Sun keyboard

Strany 97

Appendices 53For example: For Stop + A, press and hold Ctrl+Shift+Alt and press Scroll Lock, then F1 + A.These key combinations will work wit

Strany 98

54 AutoView 1415/1515/2015 Switch Installer/User GuideAppendix D: Technical SupportOur Technical Support staff is ready to assist you with any

Strany 99

USA NotificationWarning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s au

Strany 100

USA NotificationWarning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s au

Strany 101

Commutateur AutoView®1415/1515/2015Guide d’installation et d’utilisationAvocent, le logo Avocent, The Power of Being There, AutoView, OutLook et OSCAR

Strany 102

vTable of ContentsList of Figures ... vi

Strany 103 - Modification de l’affichage

InstructionsCe symbole est destiné à attirer votre attention sur la présence de consignes importantes liées au fonctionnement et à la maintenance (ent

Strany 106

iiiListe des Figures...vListe des Tableaux

Strany 107 - NOTA : Cliquez sur

iv Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Chapitre 4: Opérations avancées...

Strany 108 - Annexe D : Assistance

vFigure 1.1 : Exemple de configuration du commutateur AutoView ...4Figure 2.1 : Installation horizonta

Strany 109 - NERGY STAR

vi Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Figure 3.25 : Boîte de dialogue Commutateur...

Strany 110

viiTableau 2.1 : Compatibilité avec les commutateurs classiques...12Tableau 3.1 : Symboles d’état

Strany 111 - Impr écran, puis sur Pause

viii Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015

Strany 112

1CHAPITRE1Présentation du produitCaractéristiques et avantagesLes commutateurs AutoView® 1415/1515/2015 intègrent la technologie Avocent de commutatio

Strany 113 - Balayage du système

vi AutoView 1415/1515/2015 Switch Installer/User GuideChanging Your Switch Mode...

Strany 114

2 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Mode de partage pour deux utilisateursLes commutateurs AutoView

Strany 115 - Diagnostic du système

Chapitre 1 : Présentation du produit 3Montage en cascadeChaque commutateur AutoView permet de relier directement jusqu’à 16 serveurs et peut f

Strany 116

4 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Figure 1.1 : Exemple de configuration du commutateur AutoViewMe

Strany 117 - Diffusion vers les serveurs

Chapitre 1 : Présentation du produit 5• Vérifiez la polarité et la mise à la terre des prises de courant alternatif de l’ordinateur et du moni

Strany 118

6 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015

Strany 119 - Echap pour retourner à

7CHAPITRE2InstallationDémarrageAvant d’installer le commutateur AutoView, consultez la liste ci-dessous pour vous assurer que vous disposez de tous le

Strany 120 - Echap pour annuler

8 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Figure 2.1 : Installation horizontale du commutateur AutoViewAT

Strany 121 - Opérations avancées

Chapitre 2 : Installation 9ATTENTION : Pour éviter d’endommager votre matériel et écarter tout risque d’électrocution :- Ne retirez pas la pri

Strany 122

10 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Connexion d’un serveur à l’aide d’un module AVRIQ :1. Repérez

Strany 123 - dans le menu Utilisateur

Chapitre 2 : Installation 11Dans cette configuration, l’interface OSCAR de voie locale est désactivée sur les commutateurs montés en cascade e

Strany 124

viiList of FiguresFigure 1.1: Example of an AutoView Switch Configuration ...4Figure 2.1:

Strany 125 - Annexe A : Mises à jour Flash

12 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Figure 2.3 : Configuration du commutateur AutoView 2015 avec u

Strany 126 - Mise à jour automatique

Chapitre 2 : Installation 13Figure 2.4 : Configuration du commutateur AutoView 2015 avec des commutateurs KVM classiquesUtilisateur analogique

Strany 127 - Annexes 49

14 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Figure 2.5 : Configuration du commutateur AutoView avec des co

Strany 128

Chapitre 2 : Installation 15Ajout d’un commutateur KVM classique :1. Montez le commutateur KVM principal sur votre étagère à rack. 2. Reliez u

Strany 129 - Annexes 51

16 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015

Strany 130

17CHAPITRE3Opérations de baseContrôle du système par les voies analogiquesLe commutateur AutoView est équipé d'un ou deux groupes de voies analog

Strany 131

18 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015NOTA : Vous pouvez également lancer l’interface OSCAR en appuy

Strany 132

Chapitre 3 : Opérations de base 19Sélection du serveur précédent :Appuyez sur Impr écran, puis sur Retour arrière. Cette combinaison de touche

Strany 133 - Korean Approvals

20 Guide d’installation et d’utilisation des commutateurs AutoView 1415/1515/2015Touche(s) ActionF1Permet d’afficher l’aide relative à la boîte

Strany 134 - For Technical Support:

Chapitre 3 : Opérations de base 21Fonctions de configuration de l’interface OSCARVous pouvez configurer votre commutateur AutoView à partir de

Komentáře k této Příručce